7/27/2023 0 Comments Istat test![]() ![]() ![]() Test results from the i-STAT are generally available in 10 minutes or less. For i-STAT test cartridge information and intended use, refer to individual product pages or the cartridge information (CTI/IFU) in the i-STAT Support area.Ībbott - A Leader in Rapid Point-of-Care Diagnostics. The i-STAT analyzer can measure multiple different lab values: cardiac troponin I, electrolytes, blood gas, urea, creatinine, glucose, io nized calcium, and international normalized ratio (INR). Check with your local representative for availability in specific markets. Not all products are available in all regions. GDPR Statement | Declaration for California Compliance Law. Results are available for viewing on i-STAT screen or can be printed using the option i-STAT printer LINEARITY / REPORTABLE RANGES OF i-STAT (provided by i-STAT) Measured: SODIUM 100 - 180 mmol/L POTASSIUM 2.0 - 9.0 mmol/L CHLORIDE 65 - 140 mmol/L BUN 3 - 140 mg/dL GLUCOSE 20 - 700 mg/dL Calcium, Ionized 1.0 10. Any person depicted in such photographs is a model. Photos displayed are for illustrative purposes only. Your use of this website and the information contained herein is subject to our Website Terms and Conditions and Privacy Policy. The products and information contained herewith may not be accessible in all countries, and Abbott takes no responsibility for such information which may not comply with local country legal process, regulation, registration and usage. Cardiovascular Disease: The Stats In 2001, heart disease killed more than 700,000 people in. This website is governed by applicable U.S. The i-STAT Analyzer (left) is small enough to be brought bedside. Results may be affected in the following situations: hemolysis, traumatic draw, pumping fist. The CHEM8+ CARTRIDGE is a single-use, in vitro diagnostic test that combines a battery of basic metabolic tests including sodium, potassium, chloride, ionized calcium, total CO (2), glucose, blood urea nitrogen (BUN) and. Prolonged tourniquet application (venous stasis) and forearm exercise may decrease pH due to localized production of lactic acid. (25 Tests) Note: No returns or exchanges will be made after purchase. The i-STAT System single-use cartridges are designed to reduce the. Specimens must be free of clots and fibrin strands. No use of any Abbott trademark, trade name, or trade dress in this site may be made without the prior written authorization of Abbott, except to identify the product or services of the company. The most comprehensive menu of tests in a single platform. Unless otherwise specified, all product and service names appearing in this Internet site are trademarks owned by or licensed to Abbott, its subsidiaries or affiliates. ![]() This page is only accessible to registered i-STAT customers. Reference ranges (sometimes referred to as normal ranges) in the default Customization profile can be found behind login on the i-STAT Cartridge and Test Information (CTI) Sheets/Instructions for Use (IFU) page.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |